Graco HIP e710 Series Instructions-Parts List Manual
Graco HIP e710 Series Instructions-Parts List Manual

Graco HIP e710 Series Instructions-Parts List Manual

Dc 2–ball piston pumps

Advertisement

Quick Links

Instructions-Parts
e710 DC
DC 2–Ball
2–Ball Piston
e710
e710
DC
2–Ball
Electric drive
drive piston
piston pumps
pumps for
Electric
Electric
drive
piston
pumps
For
For
For professional
professional use
professional
use only.
use
Important
Important Safety
Important
Safety Instructions
Safety
Read all warnings and instructions in this manual. Save
instructions.
instructions.
instructions.
See Technical Specifications for
Maximum Working Pressure.
See page 3 for model part numbers and
approvals information.
Piston Pumps
Piston
for supercritical
supercritical gas
for
supercritical
only.
only.
Instructions
Instructions
PROVEN QUALITY. LEADING TECHNOLOGY.
Pumps
Pumps
gas extraction.
extraction.
gas
extraction.
Save these
Save
these
these
3A6358A
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco HIP e710 Series

  • Page 1 Instructions-Parts e710 DC DC 2–Ball 2–Ball Piston Piston Pumps Pumps e710 e710 2–Ball Piston Pumps 3A6358A Electric drive drive piston piston pumps pumps for for supercritical supercritical gas gas extraction. extraction. Electric Electric drive piston pumps supercritical extraction. For professional professional use professional use only.
  • Page 2: Table Of Contents

    Contents Contents Contents Models............... 3 Change the Oil..........13 Check Oil Level ........... 13 Related Manuals ..........3 Bearing Pre-Load......... 13 Warnings ............4 Wet-Cups ............ 13 Installation............7 Troubleshooting..........14 Location ............7 Repair..............15 Mount the Pump .......... 7 Dura-Flo Lowers ..........
  • Page 3: Models

    Models Models Models Models The six digit part number for your equipment is printed on the equipment identification label (L). Refer to the table below for information regarding the configuration of your equipment. Pump Matrix, page 19, for a complete list of pump part numbers.
  • Page 4: Warnings

    Take precautions to avoid such impact or contact. • All flameproof joints are critical to the integrity of the motor as approved for hazardous locations and are not repairable if damaged. Damaged parts must be replaced only with genuine Graco parts with no substitutions. 3A6358A...
  • Page 5 Warnings WARNING WARNING WARNING ELECTRIC SHOCK SHOCK HAZARD HAZARD ELECTRIC ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.
  • Page 6 Warnings WARNING WARNING WARNING TOXIC FLUID FLUID OR OR FUMES FUMES HAZARD HAZARD TOXIC TOXIC FLUID FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using. •...
  • Page 7: Installation

    Installation Installation Installation Installation Wall Mount Mount Wall Wall Mount Wall Mounting Hole Pattern, page 1. Select a solid position on a wall for the mounting bracket. The wall should be capable of supporting Installation of this equipment involves potentially the pump and accessories that will be attached hazardous procedures.
  • Page 8: Typical Installation

    Installation Hazardous Hazardous Hazardous Area Area Cabling Area Cabling and Cabling and Conduit Conduit Requirements Conduit Requirements Requirements Explosion Proof Proof Flame Proof Proof (ATEX) (ATEX) Explosion Explosion Proof Flame Flame Proof (ATEX) All electrical wiring in the hazardous area must be Use appropriate conduit, connectors, and cable encased in Class I, Division I, Group D approved glands rated for ATEX II 2 G.
  • Page 9: Connect The Power Supply

    Installation Connect the the Power Power Supply Supply Connect Connect Power Supply 3. Open the electrical compartment (S) on the motor. 4. Bring the supply wires into the electrical compartment through the 3/4–14 npt(f) inlet port. Connect the wires to the terminals, as shown in Improper wiring may cause electric shock or other Figs.
  • Page 10: Grounding

    Using Equipment See Fig. 5. Before using the equipment, open the fill cap (P) and add Graco Part No. 16W645 ISO 220 silicone-free synthetic gear oil. Check the oil level in Figure 5 Ground Wire the sight glass (K). Fill until the oil level is near the...
  • Page 11: Flush Before Using Equipment

    Installation Flush Before Before Using Using Equipment Equipment Flush Flush Before Using Equipment The pump fluid section was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a compatible solvent before using the equipment.
  • Page 12: Operation

    Operation Operation Operation Operation Startup Flushing Startup Startup Flushing Flushing To operate the pump, follow the Startup instructions for the Basic or Advanced motor in the Motor manual. NOTE: NOTE: NOTE: The Advanced E-Flo DC motors require installation of the 24P822 Control Module Accessory Kit to provide the interface for users to enter To avoid fire and explosion, always ground selections and view information related to setup and...
  • Page 13: Maintenance

    (34–40 N•m). See Fig. 7. The bearing pre-loads (R) are factory 4. See Fig. 7. Open the fill cap (P) and add Graco set and are not user adjustable. Do not adjust the Part No. 16W645 ISO 220 silicone-free synthetic bearing pre-loads.
  • Page 14: Troubleshooting

    Troubleshooting Troubleshooting Troubleshooting Troubleshooting NOTE: Check all possible remedies before disassembling the pump. NOTE: NOTE: NOTE: NOTE: NOTE: The LED on the motor will blink if an error is detected. See Error Error Code Error Code Code Troubleshooting Troubleshooting Troubleshooting in the motor manual for further information.
  • Page 15: Repair

    5. Remove the coupling nut from the piston rod (R). 6. Unscrew the locknuts (8) from the tie rods (6). 7. Separate the motor (3) and lower (7). To repair the lower, see the Dura-Flo Lower instruction manual. Contact your Graco representative for assistance. Reassembly Reassembly...
  • Page 16: Rods To The Motor

    Repair Reassemble the the Coupling Coupling Adapter Adapter and and Tie Tie Rods Rods to to to the the Motor Motor Reassemble Reassemble Coupling Adapter Rods Motor NOTE: NOTE: NOTE: Use this procedure only if the coupling 2. Screw the coupling adapter (9) into the motor adapter (9) and tie rods (6) have been disassembled shaft and torque to 90–100 ft-lb (122–135 N•m).
  • Page 17: Parts

    Parts Parts Parts Parts Dura - - - Flo Flo Pump Pump Assembly Assembly Dura Dura Pump Assembly Models, page 3 for an explanation of the pump part number. 3A6358A...
  • Page 18 Parts Part Description Part Part Description Description Pump Matrix, page 19 KIT, mounting bracket, pump; includes items 4 and 5; see manual 311619 Pump Matrix, page 19 MOTOR; Basic or Advanced; see motor manual; includes items 3a and 3b 3a▲ 16M130 LABEL, warning 16W645...
  • Page 19: Pump Matrix

    Parts Pump Matrix Matrix Pump Pump Matrix Pump Pump Pump Pump Pump Pump Mounting Mounting Mounting Floor Stand Stand Motor Motor Motor Washer Washer Washer Bolt Bolt Bolt Lower Lower Lower Pump Pump Pump Fitting Fitting Fitting Floor Floor Stand Part Part Part No.
  • Page 20: Dimensions

    Dimensions Dimensions Dimensions Dimensions A A A B B B C C C 58.00 in. (1473 mm) 17.00 in. (432 mm) 19.88 in. (505 mm) 3A6358A...
  • Page 21: Mounting Hole Patterns

    Mounting Hole Patterns Mounting Hole Hole Patterns Patterns Mounting Mounting Hole Patterns Stand Mount Mount Stand Stand Mount Dimension Dimension Dimension Measurement Measurement Measurement 19.88 in. (505 mm) 14.50 in. (368 mm) 16.88 in. (429 mm) 17.00 in. (432 mm) 3A6358A...
  • Page 22: Wall Mount

    Mounting Hole Patterns Wall Mount Mount Wall Wall Mount Dimension Measurement Dimension Dimension Measurement Measurement 17.8 in. (451 mm) 14.5 in. (368 mm) 12.4 in. (314 mm) 9.0 in. (229 mm) 5.4 in. (137 mm) 7.4 in. (187 mm) 5.3 in. (133 mm) 2.0 in.
  • Page 23: Performance Charts

    Performance Charts Performance Charts Charts Performance Performance Charts To find the fluid pressure (psi/bar/MPa) at a specific Key to to to Performance Performance Performance Charts Charts Charts fluid flow (gpm/lpm) and percentage of maximum NOTE: NOTE: NOTE: The charts show the motor operating at force: 100%, 70%, and 40% of maximum force.
  • Page 24 Performance Charts Table 3 3 3 220 220 V V V DC DC Motor Motor with with Dura Dura- - - Flo Flo 220 220 Lower Lower Table Table Motor with Dura Lower CYCLES CYCLES CYCLES PER PER MINUTE MINUTE MINUTE 2000 (1200)
  • Page 25: Technical Specifications

    1.5 quarts 1.4 liters Oil specification specification specification Graco Part No. 16W645 ISO 220 silicone-free synthetic gear oil Weight Weight Weight Pump package (motor, 1000cc Pump package (motor, 1000cc lower, stand, and tie rods): 220 lb lower, stand, and tie rods): 99.8 kg...
  • Page 26 Graco High Pressure Equipment Company’s written recommendations. This warranty does not cover, and Graco High Pressure Equipment Company shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco High Pressure Equipment Company component parts.

Table of Contents