Installation

Mechanical Setup

1. Fill displacement pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL).
2. Back-off air regulators to their full counterclockwise
position and close all shutoff valves.
3. Connect air line from an air source to the system air
inlet. See F
. 1 or F
IG
mance curves in manual 312376 to determine your
air supply flow requirements. Use a supply hose
capable of meeting the required flow.
Quick disconnects restrict flow for large air motors.

Connect Remote DataTrak to Power

100-240 Vac
The system has an IEC-C14 power input connection
located on the back of the power supply box. The user
must supply an appropriate adapter. The 100-240 Vac
supply must be capable of sourcing at least 1.2 Amps
and have supply current protection rated in accordance
with the supply wire gauge provided.
Frequency
Voltage
50-60 Hz 100-240 Vac
Have a trained electrician install and inspect power con-
nection per local code. Plug power supply cord into the
outlet on the back of the power supply box and into a
properly grounded electrical outlet. Use a zip tie, if
needed, to secure power cord in place.
16
. 2. Refer to the pump perfor-
IG
Max. Current
Phase
1.2 Amps
1
ti10433a
24 Vdc
Attach 24V Class 2 power supply to terminals on the
24V assembly: +24 Vdc to terminal 2 (+) and -24 Vdc to
terminal 5 (-). Attach protective earthing (PE) conductor
to terminal marked
.
5 (-)
PE
ti10853a
The 24 Vdc supply must be capable of supplying at least
1.2 Amps and have supply current protection rated at no
more than 2.5 Amps.
Voltage
Max. Current
24 Vdc
1.2 Amps
Have a trained electrician install and inspect power con-
nection per local code.