Lenovo ThinkSystem DM3010H Hardware Installation And Maintenance Manual page 76

Table of Contents

Advertisement

procedure for replacing an HDD is meant for spinning drives.
When a drive fails, the platform logs a warning message to the system console indicating which
drive has failed. In addition, both the fault LED on the operator display panel and the fault LED on
the failed drive are illuminated.
Before you begin
• Identify the failed disk drive by running the
system console.
The failed drive appears in the list of failed drives. If it does not, you should wait, and then run
the command again.
Depending on the drive type and capacity, it can take up to several hours for
the drive to appear in the list of failed drives.
• Determine whether SED authentication is enabled.
How you replace the disk depends on how the disk drive is being used. If SED authentication is
enabled, you must use the SED replacement instructions in the
Power
Guide. These Instructions describe additional steps you must perform before and after
replacing an SED.
• Make sure the replacement drive is supported by your platform. See the
• Make sure all other components in the system are functioning properly; if not, you must contact
technical support.
About this task
Drive firmware is automatically updated (nondisruptively) on new drives that have non current
firmware versions.
When replacing several disk drives, you must wait one minute between the removal of each failed
disk drive and the insertion of the replacement disk drive to allow the storage system to recognize
the existence of each new disk.
Procedure
Replace the failed drive by selecting the option appropriate to the drives that your platform
supports.
70
storage disk show -broken
ONTAP 9 Lenovo Encryption
command from the
Lenovo
Press.

Advertisement

Table of Contents
loading

This manual is also suitable for:

7dcv