>>>>> ERROR, please ensure the port has a shelf or plug.
END DATE: Sat Jan 3 23:12:07 GMT 2009
LOOP: 1/1
TEST END --------------------------------------------
If the system-level
diagnostics tests...
Were completed without any
failures
Resulted in some test failures
Then...
There are no hardware problems and your storage system
returns to the prompt.
a. Clear the status logs by entering the following command:
sldiag device clearstatus
b. Verify that the log is cleared by entering the following
command:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit
Maintenance
command:
halt
d. Enter the following command at the Loader prompt to boot
the storage system:
system-level diagnostics.
Determine the cause of the problem.
a. Exit
Maintenance
command:
halt
b. Perform a clean shutdown and disconnect the power
supplies.
c. Verify that you have observed all the considerations
identified for running system-level diagnostics, that cables
are securely connected, and that hardware components
are properly installed in the storage system.
d. Reconnect the power supplies and power on the storage
system.
e. Repeat Steps 1 through 7 of Running system installation
diagnostics.
mode