Settings For Changing The Control Card - Biasi RinNOVA 24S User Manual And Installation Instructions

Rinnova
Table of Contents

Advertisement

(Figure 9.13).
Figure 9.13
chimney sweep function at maximum out-
put in heating mode
• Press key 14 to vary the output in chimney
sweep mode: when the LCD displays the let-
ters cP that alternate with the temperature
of the heating water (e.g. 78), the "chimney
sweep function" is at maximum output in
heating mode (Figure 9.14);
Figure 9.14
chimney sweep function at maximum out-
put in domestic hot water mode
• Press key 14 again to vary the output in chim-
ney sweep mode: when the LCD displays the
letters dP that alternate with the tempera-
ture of the heating water (e.g. 60), the "chim-
ney sweep function" is at maximum output
MAINTENANCE
in domestic hot water mode (Figure 9.15);
Figure 9.15
• Press key 12 (Figure 9.10) to exit "chimney
sweep mode" and return to the previously
set boiler status (Figure 9.16).
Figure 9.16
9.12 Settings for changing the control
card
When the control card is replaced, it must be
configured for the exact boiler type.
Important: In order to check boiler opera-
tion and any change to parameters set in
the factory, the table shown in Figure 9.17
must be filled out with the values that are
displayed when scrolling the control card
configuration parameters.
Winter
Summer
- 63 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rinnova 28sRinnova 32s

Table of Contents