owner's information
Continuous Pilot/Intermittent Pilot (CPI/IPI)
selection
Note: Power vent models do not have a Continu-
ous Pilot option.
With the system in "OFF" position press the Mode Key (fig. 1) to index
to the CPI mode icon (fig. 19 & 20).
Pressing the Up Arrow Key will activate the Continuous Pilot Ignition
mode (CPI). Pressing the Down Arrow Key will return to IPI. A single
"beep" will confirm the reception of the command.
Figure 19
CPI/IPI Switch
This appliance comes equipped with a CPI/IPI switch. The functions of
both the CPI/IPI switch are as follows:
Continuous pilot (CPI) - A pilot that when in operation, is intended
to remain continuously ignited until it is manually interrupted.
Intermittent pilot (IPI) - A pilot that is automatically ignited when
an appliance is called on to operate and which remains continuous-
ly ignited during each period of main burner operation. The pilot is
automatically extinguished when each main burner operating cycle is
completed. The mode of the fireplace is easily changed from an inter-
mittent pilot ignition system (IPI) to a continuous pilot ignition system
(CPI) by using remote control as noted above.
The benefits of having as CPI are as follows:
- Keeps venting primed for trouble free start-up under colder weather
conditions or inversions.
- Keeps the unit glass warm, which decreases the amount of condensa-
tion on start-up
-Provides owners with flexibility to choose a traditional continuous
pilot. The primary benefit of having the IPI function is a significant
savings on fuel as the pilot will only run when there is a call for heat.
Thermostat Icon: If the thermostat icon is not present on the re-
mote transmitter, follow instructions noted below:
1. Remove one battery from the remote.
2. Press and hold down the Thermostat button on the remote.
3. Reinstall the battery(removed in Step 1) while still holding down
thermostat button.
4. If you see "Set" the thermostat option is now enabled. If you see
"Clr" the thermostat option is now disabled.
5. Repeat the procedure if the "Set" or "Clr" to remove or add the
option back to the remote did not appear.
Enable all other functions if not present on the remote transmitter,
follow instructions noted below:
1. Remove one battery from remote.
2. Press and hold both the ON/OFF and MODE button at the same
time .
3. Reinstall battery removed in Step 1 while holding both buttons—
keep holding buttons, then release the MODE button only.
4. The screen will show either "Clr" or "Set" as the first option avail-
able is to disable or enable a mode.
|
14
Regency
U39E-12 ULTIMATE™ Freestanding Gas Stove
®
Figure 20
5. "Clr" will remove a mode—use the up or down arrow while
holding down ON/OFF and MODE (mode icon will disappear
once removed).
6. Use the "MODE" button to move to the next function.
7. "Set" will add a mode —use the up or down arrow while holding
down ON/OFF and MODE (mode icon will appear when added).
8. Use the "MODE" button to move to the next function.
Note: You should never program out the fan (if installed) or CPI/
IPI mode on the remote.
Key Lock
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP Keys at the same
time (fig. 21).
To de-activate this function, press the MODE and UP Keys at the
same time.
Figure 21
Low Battery Power Detection
Transmitter
The life span of the remote control batteries depends on various
factors: quality of the batteries used, the number of ignitions of the
appliance, the number of changes to the room thermostat set point,
etc.
When the Transmitter batteries are low, a Battery Icon will appear on
the LCD display of the Transmitter (Fig. 22) before all battery power is
lost. When the batteries are replaced this Icon will disappear.
Figure 22