Group

System > SNMP > Group
The SNMP View Names are defined in the SNMP Group Access table and are based on
the User and Group Names
1. Log into your switch management page (see "Access your switch management page"
on page 5).
2. Click on System, click on SNMP, and click on Group.
3. Review the settings.
Creating SNMP View Names
Before you can create an SNMP View name, you must define a Group Name using the
SNMP User/Group page.
Enter the Group Name. This entry must be pre-defined on the SNMP
User/Group page.
Enter the Read View Name. This name is an optional field. It can be up to 31
characters in length.
Enter the Write View Name. This name is an optional field. It can be up to 31
characters in length.
Enter the Notify View Name. This name is an optional field. It can be up to 31
characters in length.
From the Security Model pull-down menu, select v3.
Enter the Security Level from the pull-down menu. The selection options are:
o
NoAuthNoPriv: This selection is the appropriate selection when no
Auth-Protocol or Priv-Protocol (no encryption) are selected on the
SNMP User/Group page.
o
AuthNoPriv: Choose this selection when encryption has been enabled
but only the Auth-Protocol has a password assigned and the Priv-
Protocol has been selected as none on the SNMP User/Group page.
o
AuthPriv: When the Auth-Protocol or Priv-Protocol have been
enabled, choose this selection.
Click the Add button.