MQ Power WHISPERWATT DCA10SPX4 Operation Manual page 39

Table of Contents

Advertisement

3. Verify that the status LED on the GFCI receptacle
(Figure 52) is ON (GREEN).
Figure 52. GFCI Receptacle (ON)
4. Press the TEST button (Figure 53) on the GFCI
receptacle and verify that the status LED turns OFF.
Figure 53. GFCI Receptacle (OFF)
5. Press the RESET button (Figure 54) to restore power
to the GFCI receptacle and verify that the status LED
is ON (GREEN).
Figure 54. GFCI Receptacle (ON/Restore)
DCA10SPX4/DCA10SPXU4 • OPERATION MANUAL — REV. #2 (10/11/22) — PAGE 39
GREEN
STATUS
LED (
ON
)
TEST
BUTTON
STATUS
LED (OFF)
RESET
BUTTON
GREEN
STATUS
LED (ON)
6. If the status LED (Figure 55) is flashing (RED),
DO NOT use the GFCI receptacle. Replace it
immediately.
Figure 55. GFCI Receptacle (Red Flashing LED)
GENERATOR STORAGE
For long-term storage of the generator the following is
recommended:
„ Drain the fuel tank completely. Treat with a fuel stabilizer
if necessary.
„ Completely drain the oil from the crankcase and refill if
necessary with fresh oil.
„ Clean the entire generator, internal and external.
„ Disconnect the battery.
„ Make sure engine coolant is at the proper level.
„ Cover the generator and store it in a clean, dry place.
„ If the generator is mounted on a trailer, jack the trailer
up and place it on blocks so the tires do not touch the
ground, or block and completely remove the tires.
MAINTENANCE
RED
STATUS LED
(
FLASHING
)