Front Panel Security Lockout (Executive Modes)

There are four levels of front panel security lockout that limit the various aspects of the
operation of the ISS from the front panel. All four of the executive modes can be enabled via
SIS commands (see
Enable Switching‑only mode or disable any mode via the front panel as follows:
1.
2.

Front Panel Menu Operation

Menu Navigation

Executive mode
Unlocked Front Panel — Unlock all front panel functions (default).
Mode 1: Lock Front Panel — Lock all front panel functions (disabled).
Mode 2: Limit Front Panel to input switching (Program, Preview, and Take) —
Disable all front panel controls except the PROGRAM, PREVIEW, FREEZE, MUTE, and
TAKE buttons.
NOTE: Only this mode can be enabled via the front panel buttons (see below).
Mode 3: Disable Program Bus only — Disable all changes to the Program bus.
NOTE: In Program lockout mode, the Preview input selection, MUTE, FREEZE,
LOGO, and all other controls remain unlocked.
Press and hold the MENU and NEXT buttons for approximately 5 seconds).
If enabled, the LCD screen displays Executive Mode Enabled.
If disabled, the LCD screen displays Executive Mode Disabled.
Release the buttons.
MENU button — Press to activate the menu system and scroll through the nine main
menus.
NEXT button — Press to move between the submenus of a selected main menu, to
activate a submenu for viewing or configuration, and to save a selection. Pressing the
NEXT button during input configuration causes the current input number and format
type to be displayed on the LCD window.
ADJUST (horizontal) [ and ADJUST (vertical) { knobs — When a submenu is
active, rotate the knobs to scroll through the submenu options and select a setting.
When one of the picture adjustment buttons is selected, rotate these knobs to change
picture settings.
Refer to the flowcharts in this chapter and to specific sections for explanations of the
knob adjustments.
NOTES:
If the MENU button is pressed while a main menu is active, the next main menu
becomes active.
If the MENU button is pressed while a submenu is active, the LCD window
returns to the main menu for the submenu.
To return to the default screens, let the switcher remain idle for 30 seconds until
the selected screen times out, or press the MENU button until the EXIT menu
appears, then press the NEXT button.
From any menu or submenu, after 30 seconds of inactivity, the ISS saves all
adjustment settings and times out to the default LCD display cycle.
on page 56).