Genlock Connections (Iss 612 Only) - Extron electronics ISS 608 User Manual

Seamless switchers
Hide thumbs Also See for ISS 608:
Table of Contents

Advertisement

Genlock Connections (ISS 612 only)

The ISS 612 can use an external signal to lock the scaler output rate to a common reference
so that down stream video devices can lock to the ISS signal without any glitches.
NOTE: If the horizontal refresh rate of the genlock source does not match the selected
output resolution, the ISS 612 reverts to vertical lock only.
Genlock can be selected via the front panel menu or SIS commands (see
page 49).
Genlock input connector (ISS 612 only) (see
K
external reference (genlock) signal for synchronization of the SDI output.
Genlock Loop Out connector (ISS 612 only) — Connect any downstream
L
equipment to synchronize additional devices.
figure 2
ISS 608 and ISS 612 Seamless Switchers • Installation
SDI Genlock
on
on page 6) — Connect an
11