Clearing thresholds
To remove the reference threshold settings from any receptacle:
1.
Shut off power to the receptacle that you want to clear by pressing its button on the
front panel. The red LED to the right of the button shuts off.
2.
Press and hold the Standby or Full button while pressing and releasing the receptacle
button. All three receptacle LEDs flash twice, indicating that the settings have been
cleared.
3.
Release the Standby or Full button that you were holding.
If desired, you can now turn power to the receptacle on again by pressing its button.

Grouping Receptacles

Two or more power receptacles can be grouped so that both their connected devices can be
controlled simultaneously. To group receptacles using the front panel, follow these steps for
each receptacle:
1.
Place the receptacle in configuration mode by pressing and holding its receptacle button
for 2 seconds. The green Power LED on the front panel flashes continually, indicating
that the unit is in configuration mode.
2.
Press each receptacle button repeatedly to cycle through the available group selections,
indicated by the LEDs beside the button, until you arrive at the setting you want for the
receptacle:
No LEDs lit — No groups (The receptacle will not be part of any grouping.)
S LED lit — Group 1
F LED lit — Group 2
Red (power) LED lit — Group 3
3.
Press either the Standby or the Full button to exit configuration mode.
Ungrouping receptacles
To remove a receptacle from a grouping:
1.
Place the receptacle in configuration mode by pressing and holding its button for two
seconds, until the green power LED flashes continually.
2.
Press the receptacle button repeatedly until none of its LEDs are lit (indicating no
groups).
3.
Press the Standby or Full button to exit configuration mode.

Front panel Security Lockout (Executive Mode)

When the PCS4 is in executive mode, it does not accept commands from the front panel. If
any button is pressed while the unit is in executive mode, the Power LED flashes three times,
indicating that the input from the front panel is not being accepted.
To enter or exit executive mode, press and hold the Standby and Full buttons simultaneously
for 2 seconds. The front panel Power LED flashes three times to indicate that the mode has
been switched.
NOTE:
If power to the PCS4 is recycled while the unit is in executive mode, the PCS4
remains in executive mode.