7 Piping installation
In this chapter
7.1 Preparing water piping
7.1.1 Water circuit requirements
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P587502-1B - 2020.12
7.1
Preparing water piping ...........................................................................................................................................................
7.1.1
Water circuit requirements ...................................................................................................................................
7.1.2
7.1.3
7.1.4
7.1.5
7.2
Connecting water piping ........................................................................................................................................................
7.2.1
7.2.2
7.2.3
To connect the water piping..................................................................................................................................
7.2.4
7.2.5
To fill the water circuit ...........................................................................................................................................
7.2.6
7.2.7
7.2.8
To insulate the water piping ..................................................................................................................................
INFORMATION
Also read the precautions and requirements in the
4
precautions" [
NOTICE
In case of plastic pipes, make sure they are fully oxygen diffusion tight according to
DIN 4726. The diffusion of oxygen into the piping can lead to excessive corrosion.
▪
Connecting piping - Legislation. Make all piping connections in accordance with
the applicable legislation and the instructions in the "Installation" chapter,
respecting the water inlet and outlet.
▪
Connecting piping - Force. Do NOT use excessive force when connecting the
piping. Deformation of the piping can cause malfunctioning of the unit.
▪
Connecting piping - Tools. Only use appropriate tooling to handle brass, which is
a soft material. If NOT, pipes will get damaged.
▪
Connecting piping - Air, moisture, dust. If air, moisture or dust gets into the
circuit, problems may occur. To prevent this:
-
Only use clean pipes
-
Hold the pipe end downwards when removing burrs.
-
Cover the pipe end when inserting it through a wall, to prevent dust and/or
particles from entering the pipe.
-
Use a decent thread sealant to seal connections.
▪
Insulation. Insulate up to the base of the heat exchanger.
▪
Freeze. Protect against freezing.
▪
Closed circuit. Use the indoor unit ONLY in a closed water system. Using the
system in an open water system will lead to excessive corrosion.
6].
7
Piping installation
|
"1 General safety
Installer reference guide
73
73
75
75
78
78
79
79
79
79
82
82
82
85
86
73