item No.

Setting the Tc time-out time

U641
In the TAD mode, set the time to check if there are any triggers for shifting to fax reception after a connected
(cont.)
telephone receives a call. Only the telephone function is available if shifting is not made within the set Tc time.
In the TAD mode, change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the +/- keys.
Description
Tc time-out time
2. Press the start key. The value is set.
Setting the Td time-out time
Sets the length of the time required to determine silent status (fax), one of the triggers for Tc time check. In the
TAD mode, change the setting when fax reception is unsuccessful or a telephone fails to receive a call. Be
sure not to set it too short; otherwise, the mode may be shifted to fax while the unit is being used as a tele-
phone.
1. Change the setting using the +/- keys.
Description
Td time-out time
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-20
Description
Setting range
1 to 255 s
Setting range
1 to 255 s
Service Manual
Initial setting
60
Initial setting
9 (120 V)/6 (220-240 V)