Setting the remote switching mode
U620
Description
Sets the signal detection method for remote switching. Be sure to change the setting according to the type of
telephone connected to the machine.
Method
1. Press the start key.
The port that is addressed by U698 is displayed when the optional dual FAX is installed.
2. Press [REMOTE MODE].
The current setting is displayed in reverse.
If the optional dual FAX has been installed and if U698 is set to [ALL] and settings for ports 1 and 2 are
not identical, the display is not highlighted.
3. Select the setting.
Display
ONE
CONT
4. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the transmission system 1
U625
Description
Makes settings for the auto redialing interval and the number of times of auto redialing.
Purpose
Change the setting to prevent the following problems: fax transmission is not possible due to too short redial
interval, or fax transmission takes too much time to complete due to too long redial interval.
Start
1. Press the start key.
The current setting is displayed in each item at port 1.
2. Select the item to be set.

Setting the auto redialing interval

1. Change the setting using the +/- keys.
The settings for both ports 1 and 2 are modified when the optional dual FAX is installed.
Description
Redialing interval
2. Press the start key. The value is set.

Setting the number of times of auto redialing

1. Change the setting using the +/- or numeric keys.
The settings for both ports 1 and 2 are modified when the optional dual FAX is installed.
Description
Number of redialing
When set to 0, no redialing is performed.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting communication control 1
U630
Description
Makes settings for fax transmission regarding the communication.
Start
1. Press the start key.
1-3-12
Description
Description
One-shot detection
Continuous detection
Setting range
1 to 9 (min.)
Setting range
0 to 15
Service Manual
Initial setting
3 (120 V)/2 (220-240 V)
Initial setting
2 (120 V)/3 (220-240 V)