Cs Remote Care Operation Under Enhanced Security Mode - Konica Minolta d-Color MF3000 PF-P08 Service Manual

Table of Contents

Advertisement

Field Service Ver. 1.1 Jun. 2010
Error code
3015
http request result problem
• Other errors were sent from the proxy
server.
3016
http request result problem
• Internal error occurred.
3017
http request result problem
• As the device application specified
MIO_REQBODY_ERROR, process was
stopped.
4103
Not Ready
• After turning the main power switch ON, the
machine tried to start http communication
though http communication was not ready to
work.
4106
Not Ready other than the ones listed above.
NOTE
• When a code other than the ones listed above is displayed, contact CSRC Server
Administrator and inform the error code.

10.13.14 CS Remote Care Operation under Enhanced Security Mode

CS Remote Care can be used even when "ON" is selected in [Administrator Settings]
[Security Settings]
However, to keep the enhanced security level, the following restrictions are accompanied.
• Only SSL communication is available.
• Error occurs if the Center tries to send the following commands.
- Command of reading and updating account track information
- Machine settings update command
Error
[Enhanced Security Mode].
10. SERVICE MODE
Solution
• Check user network environment.
• Check http server environment.
• Wait for a while and try
transmitting again.
• Wait for a while and try
transmitting again.
171

Advertisement

Table of Contents
loading

Table of Contents