7.5 Technical specifications
7.5.2

Ambient conditions

7.5.2.1

Transport and storage conditions

Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance with these regulations shall render the device warranty void.
Mechanical transport and storage conditions
The following information is for a device that is transported and stored in its original
packaging.
The device was tested according to IEC 60721-3-2 Class 2M4 with the following
amendments and limitations:
Type of condition
Free fall
Vibration according to IEC 60068-2-6 5 .. 8.4 Hz, deflection 3.5 mm
Shock according to IEC 60068-2-27
Climatic transport and storage conditions
The following information applies to a device that is transported in the original packaging and
weather-proof packaging, and stored from some time.
The device was tested according to IEC 60721-3-2 Class 2K11 with the following
amendments and limitations:
Type of condition
Temperature
Atmospheric pressure, altitude
Relative humidity
Pollutant concentration
Note
If dewing has developed, wait until the HMI device has dried completely before switching it
on.
Do not expose the HMI device to direct radiation from a heater.
112
Permitted range
≤ 1 m
8.4 ... 500 Hz, acceleration 1 g
250 m/s
, 6 ms, 1000 shocks
2
Permitted range
–20 ... 60 °C
1140 ... 660 hPa, corresponds to an elevation of -1000 to 3500 m
10 ... 90 %
SO
: < 0.5 ppm; relative humidity < 60%, no condensation
2
H
S: < 0.1 ppm; relative humidity < 60 %, no condensation
2
Operating Instructions, 09/2019, A5E31298376-AJ