7.1 Certificates and approvals
Software license agreements
If the device is supplied with preinstalled software, you must observe the corresponding
license agreements.
UL approval
Underwriters Laboratories Inc., to
● UL 508 (Industrial Control Equipment)
● CSA C22.2 No. 142 (Process Control Equipment)
or
Underwriters Laboratories Inc., to
● UL 508 (Industrial Control Equipment)
● CSA C22.2 No. 142 (Process Control Equipment)
● ANSI/ISA 12.12.01 (Hazardous Location)
● CSA-213 (Hazardous Location)
Approved for use in
● Class I, Division 2, Group A, B, C, D T4 or
● Class I, Zone 2, Group IIC T4 or
● non-hazardous locations
Installation Instructions for cULus haz.loc.:
● The device shall be supplied from an isolating source.
● Only for use in LAN, not for connection to telecommunication circuits.
FM Approval
Factory Mutual Research (FM) conforming to
● Approval standards FM 3611, FM 3600, FM 3810, ANSI/ISA 61010-1
● CSA C22.2 No. 213
● CSA C22.2 No. 61010.1
Approved for use in
● Class I, Division 2, Group A, B, C, D T4
● Class I, Zone 2, Group IIC T4
Installation Instructions for cFMus:
WARNING – Do not remove or replace while circuit is live when a flammable or combustible
atmosphere is present.
WARNING – Substitution of components may impair suitability of the equipment.
CAUTION – To prevent injury, read the manual before use. Warning – If the equipment is
installed within an ultimate enclosure, the inner service temperature of the enclosure
corresponds to the ambient temperature of the module.
88
IFP, IFP PRO, IFP ETH
Operating Instructions, 09/2019, A5E31298376-AJ