Technical information
7.5 Technical specifications
Emission of radio interference
The following table shows the emitted interference from electromagnetic fields according to
EN 61000-6-4, measured at a distance of 10 m.
Radiated emission (emitted interference)
30 MHz to 230 MHz
230 MHz to 1000 MHz
1 GHz to 3 GHz
3 GHz to 6 GHz
Emission of radio interference voltages
0.150 MHz to 0.5 MHz
0.5 MHz to 30 MHz
See also
Notes about usage (Page 31)
7.5.2.4

Information on insulation tests, protection class and degree of protection

Test voltages
Insulation strength is demonstrated in the type test with the following test voltages in
accordance with IEC 61131-2:
Circuit
Rated voltage U
Ethernet connector
Protection class
Protection Class I in accordance with IEC 61131-2, i.e. with protective conductor.
Protection against foreign objects and water built-in units
The device meets the requirements according to IEC 60529 and UL50.
Degree of protection Explanation
Front
Rear panel
The degree of protection of the front panel can only be guaranteed if the mounting seal is
properly installed at the mounting cut-out and the cover flap of the USB interface is closed on
the Touch/Key device. Read the corresponding information in section
"Preparing the mounting cutout (Page 41)".
The degree of protection IP65 is not covered by the UL approval and was not tested as part
of the UL approval.
116
< 40 dB (μV/m) quasi-peak
< 47 dB (μV/m) quasi-peak
< 66 dB peak and < 46 dB average
< 70 dB peak and < 50 dB average
< 79 dB quasi-peak and < 66 dB average
< 73 dB quasi-peak and < 60 dB average
Insulation tested with (type test)
24 V
707 V DC or 500 V AC to other circuits / to ground
e
1500 V AC
When mounted:
IP65 according to IEC 60529
Front face only Type 4X/Type 12 (indoor use only) according to UL50
IP20
Touch protection test with standard test probes.
There is no protection against ingress by water.
IFP, IFP PRO, IFP ETH
Operating Instructions, 09/2019, A5E31298376-AJ