Platform Overload System (If Equipped) - Terex Genie SX -180 Service And Repair Manual

Table of Contents

Advertisement

Service and Repair Manual
Platform Components
11 Press the enter or previous button on the
LCD screen until EXIT is displayed.
12 Press the plus button or minus button to
select YES and then press the enter button.
13 Remove the fastener that was temporarily
installed. Close the control box door and install
the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
34
2-5
Platform Overload System (if
equipped)
Proper calibration of the platform overload system
is essential to safe machine operation. Continued
use of an improperly calibrated platform overload
system could result in the system failing to sense an
overloaded platform. The stability of the machine is
compromised and it could tip over.
How to Calibrate the Platform
Overload System (if equipped)
Note: Perform this procedure with the machine on a
firm, level surface.
1
Level the platform.
2
Determine the maximum platform capacity.
Refer to the machine serial plate.
3
Using a suitable lifting device, place an
appropriate test weight equal to that of the
maximum platform capacity at the center of the
platform floor.
SX-180
December 2018
Part No. 1268497

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx18014-101Sx18016-599Sx180h-600

Table of Contents