Shift Instructions
0000
01
0000
00
0000
03
1200
03
0000
02
The program is set up so that a rotary encoder (000000) controls execution of
SFT(050) through a DIFU(013), the rotary encoder is set up to turn ON and OFF
each time a product passes the first sensor. Another sensor (000002) is used to
detect faulty products in the chute so that the pusher output and bit 120003 of the
shift register can be reset as required.
Rotary Encoder
(00000)
(050)
SFT
1200
1201
0005
00
0005
00
1200
03
Sensor
(00001)
Sensor
(00002)
Address Instruction
00000
00001
00002
00003
00004
00005
00006
00007
00008
Section 5-14
Pusher
(00500)
Chute
Operands
LD
000001
LD
000000
LD
000003
SFT(050)
1200
1201
LD
120003
OUT
000500
LD
000002
OUT NOT
000500
OUT NOT
120003