Omron SYSMAC CVM1 Series Operation Manual page 164

Duplex system
Hide thumbs Also See for SYSMAC CVM1 Series:
Table of Contents

Advertisement

Timer and Counter Instructions
Precautions
Flags
Example
0000
00
146
D
and D
must be in the same data area, and D
1
2
wD
D
. If D
, only D
2
1
2
Note: Refer to page 101 for general precautions on operand data areas.
Content of *DM word is not BCD when set for BCD.
ER (A50003):
The CNR(236) instruction in the example below resets timers T0001 to T0005 to
their SV whenever CIO 000000 turns ON.
(236)
CNR
T0001
will be reset.
1
T0005
Section 5-13
must be less than or equal to
1
Address Instruction
Operands
00000
LD
000000
00001
CNR(236)
T0001
T0005