Troubleshooting; Customer Service; Messages Of The Software - Dürkopp Adler D869 e-con Operating Instructions Manual

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Troubleshooting

Code
Type
1000
Error
1001
Error
1002
Error
Operating Instructions D869 e-con - 00.0 - 06/2023
10 Troubleshooting

10.1 Customer Service

Contact for repairs and issues with the machine:
Dürkopp Adler GmbH
Potsdamer Str. 190
33719 Bielefeld, Germany
Tel. +49 (0) 180 5 383 756
Fax +49 (0) 521 925 2594
Email: service@duerkopp-adler.com
Internet: www.duerkopp-adler.com

10.2 Messages of the software

Possible cause
Sewing motor encoder
plug (Sub-D, 9-pin) not
connected
Sewing motor error
Sewing motor plug (AMP)
not connected
Sewing motor insulation
error
Remedial action
• Connect encoder cable to the control,
• use correct connection
• Check connection and plug in
• Test sewing motor phases (R = 2.8Ω,
high impedance to PE)
• Replace encoder
• Replace sewing motor
• Replace control
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
183