Draining The Water-Oil Mixture - Dürkopp Adler D869 e-con Operating Instructions Manual

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

144
To adjust the operating pressure:
1.
Pull the pressure regulator (1) up.
2.
Turn the pressure regulator until the pressure gage (2) indi-
cates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure regulator (1) down.
6.3.2

Draining the water-oil mixture

NOTICE
Property damage from excess liquid!
Too much liquid can result in damage to the machine.
Drain liquid as required.
The water separator (2) of the pressure controller will show accu-
mulation of a water-oil mixture.
Proper setting
The water-oil mixture must not rise up to the level of the filter
element (1).
Check the level of the water-oil mixture in the collection tray (2).