Supermicro X11DPH-I User Manual page 46

Hide thumbs Also See for X11DPH-I:
Table of Contents

Advertisement

Super X11DPH-i/X11DPH-T/X11DPH-Tq User's Manual
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin defi nitions.
OH/Fan Fail/PWR Fail/UID LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel (JF1) to use the UID/
Overheat/Fan Fail/PWR Fail LED connections. Pin 7 of JF1 (blue LED) is used as Front UID
LED. Pin 8 of JF1 (red LED) provides warnings for possible overheating, power failure, or
fan failure. Refer to the tables below for more information.
Status
Solid red
Blinking red (1Hz)
Blinking red (0.25Hz)
Solid blue
Blinking blue (300 msec)
BMC
ASPEED
JSDCARD1
AST2500
LAN
CTRL
Battery
BT1
MH4
MH11
MAC CODE
LE3
LE4
BAR CODE
JBT1
BIOS
Intel
PCH
JRK1
SATA2
SATA1
JL1
FANB FANA
FAN4 FAN3
Power Fail LED
Pin Defi nitions (JF1)
Pin#
Defi nition
5
3.3V
6
PWR Supply Fail
Information LED (UID/OH/PWR Fail/Fan Fail LED)
Pin Defi nitions (Pin 7 & Pin 8 of JF1)
Description
An overheat condition has occurred. (This may be caused by cable congestion).
Fan failure: check for an inoperative fan.
Power failure: check for a non-operational power supply
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
USB 2/3(3.0)
VGA
FAN5
LAN2
LAN1
IPMI_LAN
FAN6
USB 0/1(3.0)
CPU2
X11DPH-i
REV: 1.10
BIOS LICENSE
CPU1
1. Power Fail LED
COM1
2. UID/OH/PWR Fail/Fan Fail LED
1
2
Power Button
Reset Button
3.3V
UID LED
3.3V Stby
3.3V Stby
3.3V Stby
JF1
3.3V
NMI
19
20
46
Ground
Ground
1
Power Fail LED
2
OH/PWR/Fail/Fan Fail LED
NIC2 Active LED
NIC1 Active LED
HDD LED
PWR LED
Ground