Omron sysmac NA Series User Manual page 15

Programmable terminal, ladder monitor
Hide thumbs Also See for sysmac NA Series:
Table of Contents

Advertisement

Security Measures
Anti-virus protection
Install the latest commercial-quality antivirus software on the computer connected to the control
system and maintain to keep the software up-to-date.
Security measures to prevent unauthorized access
Take the following measures to prevent unauthorized access to our products.
• Install physical controls so that only authorized personnel can access control systems and
equipment.
• Reduce connections to control systems and equipment via networks to prevent access from
untrusted devices.
• Install firewalls to shut down unused communications ports and limit communications hosts and
isolate control systems and equipment from the IT network.
• Use a virtual private network (VPN) for remote access to control systems and equipment.
• Adopt multifactor authentication to devices with remote access to control systems and equip-
ment.
• Set strong passwords and change them frequently.
• Scan virus to ensure safety of USB drives or other external storages before connecting them to
control systems and equipment.
Data input and output protection
Validate backups and ranges to cope with unintentional modification of input/output data to control
systems and equipment.
• Checking the scope of data
• Checking validity of backups and preparing data for restore in case of falsification and abnormal-
ities
• Safety design, such as emergency shutdown and fail-soft operation in case of data tampering
and abnormalities
Data recovery
Backup data and keep the data up-to-date periodically to prepare for data loss.
When using an intranet environment through a global address, connecting to an unauthorized
terminal such as a SCADA, HMI or to an unauthorized server may result in network security issues
such as spoofing and tampering. You must take sufficient measures such as restricting access to
the terminal, using a terminal equipped with a secure function, and locking the installation area by
yourself.
When constructing an intranet, communication failure may occur due to cable disconnection or the
influence of unauthorized network equipment. Take adequate measures, such as restricting
physical access to network devices, by means such as locking the installation area.
When using a device equipped with the SD Memory Card function, there is a security risk that a
third party may acquire, alter, or replace the files and data in the removable media by removing the
removable media or unmounting the removable media.
Please take sufficient measures, such as restricting physical access to the Controller or taking
appropriate management measures for removable media, by means of locking the installation
area, entrance management, etc., by yourself.
NA-series Ladder Monitor User's Manual (V124)
Safety Precautions
13

Advertisement

Table of Contents
loading

Table of Contents