8 8
Technical data
8.1
Technical data
Table 8: Technical data Falcon 80/56
Name
Model
Tested in accordance with
Energy efficiency index
Energy efficiency class
Fuel
Nominal fuel load
Nominal heat output (net)
Minimum heat output (net)
Useful efficiency at nominal heat output
Useful efficiency at minimum heat output (indi-
cative)
Indirect heating function
Leak rate at 10 Pa
Emissions (at 13 % O
•
carbon monoxide (CO)
•
particles (PM)
•
organic gaseous compounds (OGC)
•
nitrogen oxides (NO
Flue gas mass flow
Flue gas temperature
Chimney draught
Flue gas connection
Weight
•
Basic appliance
•
Áppliance with adjustable height frames and
convection ventilator
Minimum insulation thickness to combustible
walls
•
side wall
•
back wall
•
floor
•
ceiling
Used materials
•
Combustion chamber side panels
Falcon 80/56
, 273 K, 1013 hPa)
2
)
x
Barbas
Falcon 80/56
EN 13229:2001-A2:2004
EN16510-1 annex D, E, F
102.1
A
Wood logs, Wood briquettes
2.8 kg
14.1 kW
10 kW
76.8 %
80 %
No
3
1.4 m
/h (at 273 K, 1013 hPa)
3
0.09 vol% (1122 mg/Nm
)
3
33 mg/Nm
3
90 mg/Nm
3
101 mg/Nm
12.9 g/s
309 ºC
12 Pa (0,12 mbar)
Ø 207 mm, suitable for a pipe with an outer di-
ameter of 200 mm
•
215 kg
•
233 kg
•
100 mm
•
100 mm
•
100 mm
•
40 mm
Cast iron
Technical data
29