Technical Data - barbas Falcon 80/56 Installation And Maintenance Manual

Table of Contents

Advertisement

8 8

Technical data

8.1
Technical data
Table 8: Technical data Falcon 80/56
Name
Model
Tested in accordance with
Energy efficiency index
Energy efficiency class
Fuel
Nominal fuel load
Nominal heat output (net)
Minimum heat output (net)
Useful efficiency at nominal heat output
Useful efficiency at minimum heat output (indi-
cative)
Indirect heating function
Leak rate at 10 Pa
Emissions (at 13 % O
carbon monoxide (CO)
particles (PM)
organic gaseous compounds (OGC)
nitrogen oxides (NO
Flue gas mass flow
Flue gas temperature
Chimney draught
Flue gas connection
Weight
Basic appliance
Áppliance with adjustable height frames and
convection ventilator
Minimum insulation thickness to combustible
walls
side wall
back wall
floor
ceiling
Used materials
Combustion chamber side panels
Falcon 80/56
, 273 K, 1013 hPa)
2
)
x
Barbas
Falcon 80/56
EN 13229:2001-A2:2004
EN16510-1 annex D, E, F
102.1
A
Wood logs, Wood briquettes
2.8 kg
14.1 kW
10 kW
76.8 %
80 %
No
3
1.4 m
/h (at 273 K, 1013 hPa)
3
0.09 vol% (1122 mg/Nm
)
3
33 mg/Nm
3
90 mg/Nm
3
101 mg/Nm
12.9 g/s
309 ºC
12 Pa (0,12 mbar)
Ø 207 mm, suitable for a pipe with an outer di-
ameter of 200 mm
215 kg
233 kg
100 mm
100 mm
100 mm
40 mm
Cast iron
Technical data
29

Advertisement

Table of Contents
loading

Table of Contents