The fireplace must have ventilation openings near the bottom and near the top of the
fireplace.
The total ventilation air inlet openings must have an area of at least 450 cm
example 2 inlet openings with an area of at least 225 cm
The total ventilation air outlet openings must have an area of at least 450 cm
example 2 outlet openings with an area of at least 225 cm
6 6 .1.3

Requirements on the chimney

Make sure that in case of use of an existing (masonry) chimney, it is in good order and
applicable for the appliance. Ask your dealer or chimney sweeper for advice.
Make sure the flue system obeys the national and local applicable regulations.
Do not connect more than one appliance to the same chimney.
The flue system must have a temperature class designation of at least T400.
The inner diameter of the existing chimney must be at least 200 mm.
Do not use more than 2 bends of 45°.
The chimney outlet must be at least 5 meter above the top of the appliance.
The chimney outlet must be at least 40 cm above the top of a sloped roof.
The chimney outlet must be at least 1 meter above a flat roof.
The chimney outlet must be free from any objects (buildings, trees, etc.) within a
horizontal range of at least 5 meter.
Make sure your fire insurance policy covers any damage caused by a chimney fire.
6.2

Preparation for installation

If applicable, make sure a 230 VAC grounded electrical connection is located near the
installation location.
Make sure the door of the appliance opens and closes correctly.
Make sure the baffle is in the correct position
Make sure the control lever can move freely to left and to right.
Make sure the ashtray is empty.
6.3

Installation procedure

Do all the procedures in this section. Optional procedures are indicated with (optional).
Falcon 80/56
Warning:
The electrical connection must be grounded.
The electrical connection must be made by a certified electrician.
Make sure the electrical connection can always be accessed.
Installation
2
. (For
2
each.)
2
. (For
2
each.)
17