6 6 .3.5

Connect the convection set (optional)

Connect the aluminum pipe to the appliance
1.
2.
3.
4.
5.
6.
7.
Falcon 80/56
On the convection air box select one
of the 2 inlet openings, identified by
"FAN", on the left or right side.
a)
Remove one (1) break out plate
in the selected convection air
inlet opening with a hammer.
b)
Put the collar adaptor in the open inlet opening.
c)
Bend out the 3 lips on the collar adaptor, to attach the collar adaptor on the inlet
opening
d)
Connect a flexible aluminum pipe (B) on the collar adaptor (A). Use a hose
©
clamp
).
Connect the flexible aluminum pipe to a fitting box in the chimney breast
On the appliance, remove the two
break out plates in the convection air
outlet openings with a hammer.
Put the collar adaptors in the open
outlet openings.
Bend out the 3 lips on each collar
adaptor, to attach the collar adaptor on the outlet opening.
Connect the flexible aluminum pipes
(B) on the collar adaptors (A) . Use
©
the hose clamps
).
Connect the flexible aluminum pipes
to fitting boxes in the chimney
breast.