Installation; Installation Requirements; General Requirements; Requirements On The Installation Of The Appliance - barbas Falcon 80/56 Installation And Maintenance Manual

Table of Contents

Advertisement

Installation

6 6
Installation
6.1

Installation requirements

6.1.1

General requirements

Make sure the floor is made of concrete or a solid pedestal of non-combustible
material.
Make sure the floor can support the weight of the appliance. Refer to chapter
weight of the appliance.
Make sure that the floor temperatures below and in front of the appliance cannot be
higher than 85 °C, during use of the appliance.
The graph shows the minimum depth of a non-combustible floor in front of the
appliance in relation to the installation height of the appliance. If the underside of the
door is 30 cm above the floor, the minimum depth of the non-combustible floor is
approx. 24 cm.
The non-combustible floor must have a width that extends at least 150 mm from each
side of the appliance.
Make sure the room where the appliance is installed is properly ventilated.
6.1.2

Requirements on the installation of the appliance

Do not install the appliance against a combustible rear wall or combustible side wall.
The appliance must be installed minimum 10 cm from a non-combustible wall.
If a wooden beam is present above the appliance, make sure it is protected against
direct heat radiation. Make sure to put an insulation plate with a thickness of minimum
30 mm between the wooden beam and the appliance, with an air gap of minimum 1
cm between the insulation plate and the wooden beam.
Make sure that combustion air can flow into the appliance without obstruction.
If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
Make sure the distance between the convection air outlet openings and the ceiling
above is at least 50 cm.
Make sure the distance between the convection air outlet openings and a neighboring
wall is at least 20 cm.