Final check on the appliance

1.
2.
3.
4.
Contact your dealer if the final check shows a defect.
24
N N ote:
Make sure the thickness of any plastering is taken into account when the
brickwork is being build.
Do not use masking tape on the appliance. Masking tape damages the
paint on the appliance.
If you use other material than bricks, install the material in accordance with
the instructions of the supplier of the material
If you use other material than bricks, refer to the instructions of the supplier
of the used material for information on the need to use a mantle iron.
Identify the positions where the ventilation air inlet grates and the ventilation air outlet
grates must be put. Refer to
openings.
If applicable, identify the positions where the fitting boxes of the convection air inlets
and convection air outlets must be put. Refer to
distances from ceiling and neighboring wall.
Identify the position where the dimmer for the convection ventilator must be put.
Build the brickwork around the appliance up to the upper frame around the glass.
a)
Install the fitting boxes of the ventilation air inlets.
b)
If applicable, install the fitting boxes of the convection air inlets.
c)
If applicable, install the dimmer of the convection ventilator.
If applicable, install a mantle iron to support the brickwork above the appliance. Put
the mantle iron on both sides of the brickwork. Maintain a space of at least 3 mm
between the appliance and the mantle iron.
If applicable, install the flexible aluminum pipes of the convection set. Refer to
Build the fireplace around the appliance.
a)
Install the fitting boxes of the ventilation air outlets.
b)
If applicable, install the fitting boxes of the convection air outlets
Install the frame around the appliance.
Caution:
Wait 4 weeks after the installation before you use the appliance. The cement
used for the fireplace needs to harden and to avoid damage to the plaster
work.
Make sure the door closes and opens easy.
Make sure the control lever moves easy to left and right without undue noise.
Make sure all cast iron plates and the baffles are in the correct position.
When applicable: Start the convection ventilator and make sure the ventilator does
not make an unusual noise (grinding sound). A soft hum is not an unusual sound.
6.1.2
for requirements on the size of the ventilation air
6.1.2
for requirements on minimum