Rotating A Connector On The Motor - Siemens SIMOTICS S-1FT7 Configuration Manual

Synchronous motors
Table of Contents

Advertisement

Electrical connection
8.3 System integration
8.3.1.1

Rotating a connector on the motor

Power connectors and signal connectors can be rotated to a different angle to a limited
extent.
Use a suitable socket connector to rotate the angled connector.
Unscrew and open the socket connector completely to avoid damaging the pin contacts.
On encoders with an integrated Sensor Module (DQI), the cable outlet toward the top is fixed
and cannot be changed.
Note
Rotating the connectors
• Do not exceed the permissible range of rotation.
• To ensure the degree of protection, do not rotate more than 10 times.
• Rotate the connector using a mating connector that matches the connector thread. Only
rotate Sensor Modules by hand. Use of tools is not permissible.
Ability to rotate the power connector on motors with natural cooling / water water cooling and DRIVE-
CLiQ interface 1FT7□□□-□A□□□-□X□□, 1FT7□□□-□W□□□-□X□□; X = B, C
Table 8- 3
Rotation range of the power connector
Motor
Angle α
1FT703☐
130 °
1FT704☐
1FT706☐
130 °
1FT708☐
1FT706☐
160 °
1FT708☐
170 °
1FT710☐
190 °
1FT713☐
1FT7117
cannot be rotated
1FT713☐
Figure power connector, connector size M23
370
Angle β
Connector size
130 °
M23
135 °
M23
120 °
120 °
M40
135 °
M58
Drawing
S-1FT7 synchronous motors
Configuration Manual, 09/2018, A5E45099423B AA