Connecting
7.4 System integration
Cable cross-section and current-carrying capacity
Cable cross-section and current-carrying capacity
Derating factors for power and signal cables
Derating factors for power and signal cables
7.4.1.2
Rotating the connector at the motor
Power connectors and signal connectors can be rotated to a limited extent.
Use a suitable socket connector to rotate the angle plug.
Unscrew and open the socket connector completely to avoid damaging the pin contacts.
130
Cross-section
Current-carrying capacity rms; AC 50/60 Hz or DC for routing type
mm
2
0.20
0.50
0.75
0.75
1.00
1.50
2.50
4
6
10
16
25
35
50
Ambient air temperature [°C]
30
35
40
45
50
55
60
B1 / A
Electronics (according to EN 60204-1)
-
-
-
Power (according to EN 60204-1)
8.6
10.3
13.5
18.3
24
31
44
59
77
96
117
Derating factor according to EN 60204-1, Table D1
Operating Instructions, 12/2022, A5E47360747B/RS-AC
B2 / A
4.3
7.5
9
8.5
10.1
13.1
17.4
23
30
40
54
70
86
103
1.15
1.08
1.00
0.91
0.82
0.71
0.58
SIMOTICS S-1FG1 servo geared motor
C / A
4.4
7.5
9.5
9.8
11.7
15.2
21
28
36
50
66
84
104
125