Environmental Conditions - Siemens SIMOTICS S-1FT7 Configuration Manual

Synchronous motors
Table of Contents

Advertisement

Description of the motors
2.3 Technical features and environmental conditions
Static torques for the 1FT7 High Dynamic, water cooling
2.3.4

Environmental conditions

You can classify the environmental conditions for stationary use at weather-protected
locations according to the standard DIN IEC 60721-3-3. The environmental effects and their
limit values are defined in various classes in this standard.
With the exception of environmental influences "Low air temperature", "Condensation" and
"Low air pressure", you can assign SIMOTICS S-1FT7 servomotors to climate class 3K4.
The following temperature ranges apply for naturally-cooled and forced-ventilation motors.
Table 2- 2
Environmental parameter
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
30
Environmental conditions based on climate class 3K4
Low air temperature
High air temperature
Low relative humidity
High relative humidity
Low absolute humidity
High absolute humidity
Rate of temperature change
Low air pressure
4)
High air pressure
2)
Solar radiation (insolation)
Thermal radiation
Air movement
3)
Condensation
Wind-driven precipitation
(rain, snow, hail, etc.)
1)
Configuration Manual, 09/2018, A5E45099423B AA
Unit
Value
°C
- 15
°C
+ 40
%
5
%
95
g/m
1
3
g/m
29
3
°C/min
0.5
kPa
89
kPa
106
W/m
700
2
-
-
m/s
1.0
-
Not permissible
-
-
S-1FT7 synchronous motors

Advertisement

Table of Contents
loading

Table of Contents