Mechanical properties
3.1 Cooling
Connecting motors in series
We can only recommend series connection of motors if:
● The required flow rates of the motors are approximately the same (< factor of 2)
● The maximum cooling water inlet temperature is maintained in the second or third motor.
Note
Derating of series-connected motors
The heat dissipation of the cooling water in the second and third motor may require derating
(see Table Derating factors).
3.1.3.3

Specification of the cooling water

Cooling water
Table 3- 9
Chloride ions
Sulfate ions
Nitrate ions
pH value
Electrical conductivity
Total hardness
Dissolved solids
Size of entrained particles
Corrosion protection
Anti-freeze protection
Other coolants (not water-based)
If you use different cooling media (e.g. oil, cooling lubricant), derating may be necessary in
order to comply with the thermal motor limit.
Note
Derating when using other cooling lubricants
Derating is required for water-oil mixtures with more than 10% oil.
46
Water specification as coolant
Quality of the water used as coolant for motors with alumi-
num, stainless steel tubes + cast iron or steel jacket
< 40 ppm, can be achieved by adding deionized water.
< 50 ppm
< 50 ppm
6 ... 9 (with aluminum 6 ... 8)
< 500 μS/cm
< 170 ppm
< 340 ppm
< 100 μm
0.2 ... 0.25% inhibitor Nalco TRAC100 (previously 0GE056)
If necessary 20 ... 30% Antifrogen N (manufacturer Clariant)
Configuration Manual, 09/2018, A5E45099423B AA
S-1FT7 synchronous motors