DC Characteristics
(MTC-30132 SHLIC,
unless otherwise noted)
Unless otherwise stated, these charac-
teristics apply for the operating condi-
tions specified above. All parameters
are explicitly or implicitly tested during
production at the operating conditions
unless they are marked with a *, where
they are guaranteed by design. Para-
meters marked with ** are meant as
user information only. Tests are per-
formed using an equivalent of the appli-
cation schematic.
Power Supply Currents
Table 19: Power Supply Currents
Symbol
Parameter
Ibatr
BATR current (IL = 0)
Ibats
BATS current (IL = 0)
Ivdd
VDD current (IV3V=0)
Pcc
Power dissipation of CODSP
(@ 3,45V V3VA and V3VD)
Notes:
IL is the line current, i.e. these parameters are measured without line current.
IV3V is the load current in pin V3V
The maximum values in the table are valid for the full battery voltage ranges :
-18V to -72V for ringing battery BATR
-18V to -35V for battery BATS. (BATR must be always the most negative one)
In case of sleep mode activation. See tables "Data Ram: Memory Map, description and default val-
ues" for programing values.
Test Conditions
Power
RNG=0
Up
RNG=1
Power
RNG=0
Down
RNG=1
Power
RNG=0
Up
RNG=1
Power
RNG=0
Down
RNG=1
PowerUp
PowerDown
PowerDown
PowerUp
1 line active
PowerUp
2 lines active
29
MTK-40131
Limits
Min.
Typ.
Max.
0.35
0.5
3.5
5.0
0.35
0.5
2.5
3.5
3.5
5
3.5
5
1.5
2.5
0.5
3
5.5
2.5
4
30
140
180
Unit
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mW
mW
mW