Metering Injection

Metering pulses of selectable frequency
(12 or 16 kHz) and programmable
amplitude can be injected into either
analog channel independently. The
width of the injected pulse is determi-
ned by the user ("on/off mode"), or by
an internal timer ("burst mode") which
can be set by the user from 2ms to 510
ms in steps of 2ms. The metering signal
is always a multiple of half metering
periods. See fig. 12.
/MPI
metering
/MPI
metering

Fig. 12: Metering pulse timing diagrams.

The metering level on the line is set by: Vlm = (Vgen . Zm)/(Zm + Zcom)
where:
Vlm
= metering pulse level on the line
Vgen
= set level of the metering generator
Zm
= impedance of the metering load
Zcom
= CO impedance at the metering frequency.
Metering is initiated on a channel by
an active low state on the correspond-
ing /MPI bit in the GCI C/I byte.
on/off mode
burst mode
t
mburst
21
MTK-40131
The metering level Vgen is selectable
from 0 to a maximum level of
230mVrms (500m line with
Zco=900Ω) in 15 linear steps. The
internal tolerance on the metering sig-
nal level is ±10%.