Table 1-1. Product Matrix - Emerson Rosemount Analytical Oxymitter 4000 Instruction Manual

Hazardous area oxygen transmitter
Table of Contents

Advertisement

Instruction Manual
IB-106-340C Rev. 4.1
July 2004
OXT4C
OXYMITTER 4000 - EXPLOSION PROOF - IN SITU OXYGEN TRANSMITTER
Explosion Proof Oxygen Transmitter - Instruction Book
Code
Sensing Probe Type with Flame Arrestor
1
Ceramic Diffusion Element Probe (ANSI 3 in. 150 lbs)
2
Snubber Diffusion Element (ANSI 3 in. 150 lbs)
3
Ceramic Diffusion Element Probe (DIN 2527) - 1/4 in. Tube Fittings
4
Snubber Diffusion Element (DIN 2527) - 1/4 in. Tube Fittings
5
Ceramic Diffusion Element Probe (JIS)
6
Snubber Diffusion Element (JIS)
7
Ceramic Diffusion Element (ANSI 3 in. 300 lbs)
8
Ceramic Diffusion Element (ANSI 4 in. 300 lbs)
Code
0
1
2
3
4
5
6
OXT4C
3
3
1-14
Description and Specifications

Table 1-1. Product Matrix

Probe Assembly
18 in. (457 mm) Probe
18 in. (457 mm) Probe with 3 ft (0.91 m) Bypass
18 in. (457 mm) Probe with Abrasive Shield
3 ft (0.91 m) Probe
3 ft (0.91 m) Probe with Abrasive Shield
6 ft (1.83 m) Probe
6 ft (1.83 m) Probe with Abrasive Shield
Code
Mounting Adapter - Stack Side
0
No Adapter Plate ("0" must be chosen under "Mounting Adapter - Probe Side" below)
1
New Installation - Square weld plate with studs
2
Model 218 Mounting Plate (with Model 218 Shield Removed)
3
Competitor's Mount
Code
Mounting Adapter - Probe Side
0
No Adapter Plate
1
Probe Only (ANSI)
2
New Bypass or New Abrasive Shield (ANSI)
4
Probe Only (DIN)
5
New Bypass or New Abrasive Shield (DIN)
7
Probe Only (JIS)
8
New Bypass or New Abrasive Shield (JIS)
Code
11
12
13
14
21
22
23
24
1
1
11
Hazardous Area Oxymitter 4000
(1)
(1)
(1)
(2)
Electronic Housing and Filtered Customer Termination - NEMA 4X, IP66
®
HART
Integral Electronics, Standard Filtered Termination,
ATEX Certification
®
HART
Integral Electronics, Transient Protected Filtered Termination,
ATEX Certification
®
HART
Remote Electronics (requires cable), Standard Filtered Termination,
ATEX Certification
®
HART
Remote Electronics (requires cable), Transient Protected Termination,
ATEX Certification
®
HART
Integral Electronics, Standard Filtered Termination,
CSA/FM Certification
®
HART
Integral Electronics, Transient Protected Termination,
CSA/FM Certification
®
HART
Remote Electronics (requires cable), Standard Filtered Termination,
CSA/FM Certification
®
HART
Remote Electronics (requires cable), Transient Protected Termination,
CSA/FM Certification