3 Printer operation

3 Printer operation
This chapter provides information about printer operation.
3.1 Printing Media Calibration &
Configuration
You will want the printer to work properly before starting your print jobs. To
do this, you need to calibrate the media sensor. Printers provide
transmissive and reflective sensor calibration. Take the following steps to
use them.
1. Make sure the media is properly loaded, the print module is closed, and
the printer's power switch is set to the OFF position.
2. Press and hold the FEED button, and turn on the printer.
3. Both status lights glow solid Amber for a few seconds. Next, they turn to
green shortly, and then turn to other colors. Do one of the following to
select the sensor:
If you want to calibrate the transmissive sensor, when LED 2 turns to
red and LED 1 turns to green, release the FEED button immediately.
If you want to calibrate the reflective sensor, when LED 2 turns to
Amber and LED 1 turns to green, release the FEED button immediately.
4. Press the FEED button. The media calibration is complete after the
printer feeds 3-4 labels and stops.
Printing Media Calibration & Configuration