Chapter
4
LinePrinter+

Select SFCC

This parameter allows you to select which ASCII codes will function as the
Special Function Control Code (SFCC) command delimiter.
P-Series codes can use hex 00 through hex 7F. Options include the following:
ESC (hex 1B)
SOH (hex 01)
ETX (hex 03)
CIRCUMFLEX (hex 5E)—also called caret (^)
TILDE (hex 7E)—(~)
NOTE: SOH, ETX and ESC are non-printables. The characters (^) and (~)
EVFU Select
Controls how the printer handles vertical formatting.
Enable. Enables the VFU and selects P-Series compatible Electronic
Vertical Format Unit (EVFU).
Disable. Disables all VFU processing.
Alt. Set 80-9F
Determines whether the printer processes ASCII codes hex 80 through hex
9F as control codes or as printable characters.
Character Set
Specifies a character set. To use one of these sets, choose the desired set
and press ENTER. Two groups of character sets (IBM PC and ECMA Latin 1)
have Primary and Extended Subsets. To use one of these sets, choose the
group name and press ENTER, then choose the desired set within the
Primary or Extended subset and press ENTER. Both the group and the
desired set will be starred to indicate your selection.
SFCC d Command
Even dot plot. This option interprets SFCC d Command as even dot plot.
Double high. This option interprets SFCC d Command as double high.
Select this option for backward compatibility.
88
are printable; however, do not use them as printables in the host data
stream if either is chosen as a delimiter, or print errors will occur.