Chapter
7
Using the RibbonMinder
Using the RibbonMinder
This chapter outlines how to configure the RibbonMinder each time you
change your ribbon, as well as how to set the options available with the
RibbonMinder feature.
Configuration
This section explains how to unlock the ENTER key, find the RibbonMinder
options, make changes, exit the configuration menu, and lock the ENTER
key.
Following this section are procedures for changing each RibbonMinder
option. To avoid repetition, references are made to Table 20 for entering the
configuration menu.
NOTE: All RibbonMinder options are automatically saved in NVRAM when
As you perform the following steps, refer to the RibbonMinder menu diagram
shown in Figure 48.
RIBBON
MINDER
New Ribbon
Press ENTER
to reset ribbon
life to 100%. A
new ribbon
must be
installed after
setting the
ribbon life to
100%.
150
selected.
Ribbon Action
Ribbon Size
=
>
Disable*
Press
or
Display
increase or
Fault
decrease size.
60 yards*
(1-255)
Default is 100
yards for
cabinet model.
Figure 48. RibbonMinder Menu Diagram
* = Factory Default
RIbbon Adjust
Ribbon Fault
=
>
to
Press
or
to
New Ribbon*
increase or
Do Nothing
decrease.
0*
(-99% to 99%)
To view options, press:
To select an option, press ENTER.
To return to main menu, press
CLEAR.
To exit menu, press ONLINE.
* = Default Setting
>
Down
=
Up
<
Next
;