Sony MLS-X1 User Manual page 411

Live production processor system
Hide thumbs Also See for MLS-X1:
Table of Contents

Advertisement

3
Display the target page to set.
Select a tab to change the page (Page 1 to Page 14) to
display.
4
Press the target button to set in [Button Assign].
The [Select Function] window appears.
The functions that can be assigned to the cross-point
pad button are displayed in the [Select Function]
window.
Select a tab to change the function to display.
When a switcher bank is selected in the [Select
Bank] group
[Row-1 Bus] tab to [Row-4 Bus] tab: Switcher bank
buses to assign to the 1st row to 4th row
[Row-1 Aux] tab to [Row-4 Aux] tab: AUX buses
to assign to the 1st row to 4th row
[Row-1 Func] tab to [Row-4 Func] tab: Functions
to assign to the 1st row to 4th row
[Others] tab: Other functions
[Table/Macro] tab: Cross-point assign tables and
macro registers
When an AUX bus control block is selected in the
[Select Bank] group
[Row-3/4 Func] tab: Functions to assign to the 3rd
row/4th row
[Others] tab: Other functions
[Macro] tab: Macro registers
5
Set the button for the function to assign to the on
state.
[Table/Macro] tab or [Macro] tab, table selection
buttons/register selection buttons
Set the radio button to the on state, press the input
field, and enter the table number/register number in
the numeric keypad window.
To release the assignment
Set the [No Assign] button to the on state.
6
Press [OK].
To set a page name
Press the [Page Name] button and enter a page name (up
to 12 characters) using the keyboard.
To set the page recall function
You can set to display a particular page when a cross-
point pad button is pressed.
Buttons configured with a page recall function have a
white frame around the cross-point pad buttons in the
control panel.
Note
The page recall function can be assigned to buttons in the
cross-point pad to which already have another function
assigned.
1
Press the target button to set in [Jump Page Assign].
The [Select Page] window appears.
2
Set the button for the page to recall to the on state.
To release the page recall function setting
Set the [No Assign] button to the on state.
3
Press [OK].
To release all button assignments
Press the [All Clear] button.
The functions assigned to the buttons on the selected page
and the page recall function settings are deleted.
About re-entry signal selection buttons
By default, the following signals are assigned to cross-
point button numbers 285 to 300.
The re-entry signal selection buttons in the cross-point
pad use signals assigned to button numbers 285 to 290
and button numbers 293 to 298.
a)
Function name
Row-n Xpt Btn
No.285
Row-n Xpt Btn
No.286
Row-n Xpt Btn
No.287
Row-n Xpt Btn
No.288
Row-n Xpt Btn
No.289
Row-n Xpt Btn
No.290
Row-n Xpt Btn
No.291
Row-n Xpt Btn
No.292
Row-n Xpt Btn
No.293
Row-n Xpt Btn
No.294
Row-n Xpt Btn
No.295
Row-n Xpt Btn
No.296
Row-n Xpt Btn
No.297
411
Cross-point
Logical
Signal
button
V/K pair
number
number
285
213
M/E-1 Out1
286
221
M/E-2 Out1
287
229
M/E-3 Out1
288
205
P/P Out1
289
237
M/E-4 Out1
290
245
M/E-5 Out1
291
284
(black signal)
292
284
(black signal)
293
217
M/E-1 Out5
294
225
M/E-2 Out5
295
233
M/E-3 Out5
296
209
P/P Out5
297
241
M/E-4 Out5