Equipotential
bonding
Exposed terminals after cover removal
To gain access to the connection terminals, the cover above must
first be removed. The connecting cable must be routed through the
toroid to the terminals.
The machine is supplied ex-works for 3N AC 50–60 Hz. See data
plate for voltage data.
An equipotential bond with good contact connection must always be
provided in accordance with all national and local regulations.
The electric heating is set ex-works to 15 kW (PW 6163), 24 kW
(PW 6243),
30 kW (PW 6323).
The minimum liquor level to activate the heater is 70 mm water
column.
The motor is protected against overload by a motor thermo-switch.
Please refer to the wiring diagram and installation plan provided.
These plans are important for the electrical connection.
Connecting the dispenser pumps (depending on
country)
Connection terminals for 4 time-controlled dispenser pumps, which
can be operated without a multifunction module, are located behind
the cover adjacent to the electrical connection. See enclosed wiring
diagram.

Steam connection (depending on country)

For steam-heated machine variants, the steam connection must only
be carried out by an authorised installation technician. The steam
valve and condensate trap are available from Miele.
Installation
81