6.
Tighten bolts that hold braces.
7.
Adjust extension table so it is flat (both
flush and parallel) with main table. This can
be done by loosening mounting bolts and
adjusting feet up/down as needed. Figure 29
shows extension table installed on saw.
Figure 29. Extension table installed.
8.
Tighten extension table mounting bolts.
Tighten hex nuts on feet against legs so they
will not move.
Saw Blade
Install saw blade as outlined in Blade Installation
on Page 33.
-26-
Table Insert
To install table insert:
1.
Install table insert into opening of table saw
over blade.
Adjust table insert set screws to make sure
2.
insert is flush with table, using a straightedge
as a guide (see Figure 30).
Figure 30. Adjusting insert flush with table.
Follow instructions in Checking Fence
3.
Parallelism, then proceed to Blade Guard
to complete remaining assembly steps.
Checking Fence
Parallelism
Verify that the fence is parallel to the blade/miter
slot and that this setting did not change dur-
ing shipping (refer to "Clamping Pressure and
Parallelism" on Page 72). The blade was set par-
allel with the miter slot at the factory—this affects
whether the fence is parallel when mounted to the
table.
Blade Guard
Install the blade guard as instructed in "Installing
Blade Guard & Spreader" on Page 34.
Model G1023RL Series (Mfd. Since 02/21)