Setting Port Speed
The rs232PortInSpeed, rs232PortOutSpeed, and
rs232AsyncPortAutobaud are related for the Annex's
asynchronous ports.
To set the port to autobaud, you must first set
rs232AsyncPortAutobaud to enabled (1) and then set either
rs232PortInSpeed or rs232PortOutSpeed to zero. Setting the
port speed to zero when rs232AsyncPortAutobaud is disabled
results in a bad value error.
To disable autobaud, you must first set the port speed to a
non-zero value, and then set rs232AsyncPortAutobaud to
disabled(2). This ensures that the port is not left in a state
without a declared speed.
For example, you can set a port to 9600/autobaud by setting
9600 in rs232PortInSpeed or rs232PortOutSpeed and then setting
rs232AsyncPortAutobaud to enabled(1).
RFC 1318 Parallel Printer MIB Restrictions
The Annex supports:
paraNumber.
paraPortTable.
paraInSigTable.
The Annex does not support:
paraOutSigTable.