30 Chapter 2 Installing option cards in the Contivity 1100
To install a new LAN, WAN, or serial option card:
1
2
3
4
5
6
7
8
9
314961-E Rev 00
Use the Web GUI or the command line interface to shut down the gateway.
Web GUI: Choose Admin > Shutdown. Select the option to power off the
gateway after shutdown.
Command line interface: Use the
system. For example, enter
"Upgrade hardware"
command, see the Reference for the Contivity Secure IP Services Gateway
Command Line Interface).
Wait for the system to shut down.
Turn off the Contivity 1100 power.
The power switch and power outlet are located on the rear of the Contivity
1100.
Disconnect the power cord from the power outlet and then disconnect the cord
from the Contivity 1100.
Danger: Make sure to turn off the Contivity 1100 and unplug it before
you attempt to remove or install an option card.
Remove the cables attached to the ports of the Contivity 1100.
If there are option cards currently installed, unscrew the 2 screws on each
bracket and remove the bracket.
Caution: Unscrew the option card brackets before you remove the
cover from the Contivity 1100 or you will damage the option cards.
Remove the 4 screws located on the sides of the Contivity 1100.
Slide the chassis cover away from the base.
The Contivity 1100 system board is now exposed.
location of the option card slots on the system board.
Locate the slot where you plan to install the new or replacement option card
(see
Table 10 on page
reload
reload power-off disable-logins
(for the complete syntax of the
29).
command to shut down the
reload
Figure 12
shows the