Known problems in this release

This section describes known problems with this release and suggests solutions
to these problems, if solutions are available.
M3902 digital telephone sets connected to Remote Gateway 9150
units connected to CS 1000 PBXs have display irregularities in
survivable mode (Q00352179)
When CS 1000 PBXs go into survivable mode, M3902 digital telephone sets
connected to Remote Gateway 9150 units connected to these PBXs react
abnormally. These digital telephone sets temporarily present abnormal messages
in their telephone set displays.
RLC maintenance LED stays off when RLC is disabled using DISS
command in Load 32 on CS 1000 PBXs (Q00352255)
Maintenance LEDs on RLCs installed in CS 1000 PBXs do not respond
properly to the Load 32 (LD32) command, Disable Shelf (DISS). The LED is
off, or dark, when the RLC is operating correctly. The LED's being on, or lit,
usually indicates that the RLC is disabled or experiencing some sort of a
problem. When the maintenance LED remains off after you enter the DISS
command, enter the Disable Card (DISC) command for that card.
Configuration Wizard displays Error: 1250 - Invalid Command
(Q00541393)
After you re-set the configuration of a Remote Gateway 911x series unit,
altering the unit's configuration with the Configuration Wizard results in the
following error: 1250 - Invalid Command. After re-setting the configuration of a
Remote Gateway 911x series unit, you must re-enter the configuration manually.
20
1.6.0 Release Notes for Remote Gateway 9100 Series and RLC