Issues Fixed in this Release
(773) A change to the proxy exclusion list on the Network > Proxies
•
page does not cause the Application Gateway to restart.
Workaround: Go to the Administration > Maintenance page and click
Restart.
(2027) After changing the root password, you might be asked to enter
•
the password multiple times when attempting to access an
Administration Tool page. This issue has been observed only in
Windows Internet Explorer.
Workaround: Close and then re-open the browser window.
Alternatively, use the Mozilla browser.
(2167) If the first line of the system log contains an XML tag and the
•
system log is viewed through the Administration Tool Logging >
System Log page in Internet Explorer, the log will not display and you
will see the following error: "The XML page cannot be displayed.
Cannot view XML input using style sheet."
Workaround: This is a display issue in Internet Explorer and does not
occur in the Mozilla or Opera browsers. Alternatively view the log
from the log archive or syslog.
(2585) If all Application Gateway licenses are in use and you are
•
disabling a license from one phone in order to give the license to
another phone, you must restart the Application Gateway after
enabling/disabling the licenses.
(475) When a broadcast message exceeds one screenful of text, the
•
Application Gateway does not supply a More key to view the rest of
the message.
(557) A rescheduled message is not sent, although the clock icon
•
beside the message disappears, indicating the message was sent.
(607) On IP Phone 2007 in GXAS mode, the first attempt to launch a
•
custom application from the Application Menu results in an error
message: "drivers_http: unknown HTTP method."
(688) If the Broadcast Server interface is not used for several days, the
•
EnvoyEngine service stops and must be restarted, after which queued
messages will be sent.
(707) The Application Gateway Administration Tool does not time
•
out.
(739) Zone pages are intermittently timing out.
•