2-3-2. MR Adjustment

The inner focus lens MR adjustment is carried out automatically.
If it is not corrected, the focus will be deviated during auto focusing/manual focusing.
Subject:
Not required
Measuring equipment:
Remote commander RM-95
Adjustment page:
6F
Adjustment address:
58, 5A to 65
Specifi cations
Specifi cation 1:
40 to C0
Specifi cation 2:
03 to 78
Specifi cation 3:
88 to FD
m
. Perform the adjustment with the lens in horizontal state.
. Perform "Flange Back Adjustment" (Section 2-3-4.) after this adjustment.
. If reading/writing data on page 6F, set data:06 to page:0, address:10, and then select page F. By this data
setting, the page 6F can be selected.
After the data reading/writing fi nished, return the data on page:0, address:10 to "00".
. Check that the data of page:6, address:02 is "00".
If not, select page:6, address:01, set data:00, and press the PAUSE button.
Adjusting procedure
Order
Page
Address
1
0
01
2
6
01
3
6
02
4
0
10
5
F
5A
(6F)
5B
5C
5D
6
F
5E
(6F)
60
62
64
7
F
5F
(6F)
61
63
65
8
0
10
*1: The adjustment data will be automatically input to page:6F, address:58, 5A to 65.
Procedure after completing adjustment
Order
Page
Address
1
6
01
2
6
01
3
6
01
4
0
01
EVI-HD7V
Data
Operation
01
BD
Press the PAUSE button. (*1)
Check that the data changes to "01".
06
Check that the data of each address satisfi ed the specifi ed
value 1.
Check that the data of each address satisfi ed the specifi ed
value 2.
Check that the data of each address satisfi ed the specifi ed
value 3.
00
Data
Operation
00
Press the PAUSE button.
25
Press the PAUSE button.
00
Press the PAUSE button.
00
2-19