Procedure after completing adjustment
Order
Page
Address
1
6
4D
2
6
2C
3
6
40
4
6
41
5
6
C9
6
6
01
7
0
01
2-3-20. White Defect Adjustment
Subject:
Arbitrary subject
Measuring equipment:
Remote commander RM-95
Specifi cation:
Data of page:6 address:D3 is "00".
m
. Perform "Auto White Balance Adjustment" (Section 2-3-12) before this adjustment.
. Check that the data of page:0, address:10 is "00".
. Check that the data of page:6, address:02 is "00".
If not, select page:6, address:01, set data:00, and press the PAUSE button.
Adjusting procedure
Order
Page
Address
1
0
01
2
6
0D
3
0
10
4
B
41
(6B)
5
0
10
6
6
D0
7
6
01
8
6
02
9
6
D3
Procedure after completing adjustment
Order
Page
Address
1
6
01
2
0
10
3
B
41
(6B)
4
0
10
5
0
01
EVI-HD7V
Data
Operation
00
00
00
00
00
00
Press the PAUSE button.
00
Data
Operation
01
Check that the data is "04".
06
10
Press the PAUSE button.
00
06
21
Press the PAUSE button.
Check that the data changes to "01".
Check that the data is "00".
Data
Operation
00
Press the PAUSE button.
06
10
Press the PAUSE button.
00
00
2-41