5. CCD Output 2ch Matching Adjustment (2)

Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Adjustment Page
Adjustment Address
Note1: Shoot the clear chart with the zoom TELE end.
Note2: This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
1
0
01
2
6
2C
3
6
40
4
6
01
5
6
02
Note4: The adjustment data will be automatically input to page: F, address:
29 to 2D
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
2C
3
6
40
4
0
01
Clear chart (All white) (Note1)
F
29 to 2D
Procedure
01
Set the data.
01
Set the data.
01
Set the data.
F5
Set the data, and press PAUSE
button.
Check that the data changes to
"01" in about 50 seconds after
pressing PAUSE button.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.

6. MR Adjustment

The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value1
Specified Value2
Specified Value3
Note1: Make the lens horizontal and perform this adjustment.
Note2: Perform this adjustment before "Flange Back Adjustment".
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
02
4
F
5A
5
F
5B
6
F
5C
7
F
5D
8
F
5E
9
F
5F
10
F
60
11
F
61
12
F
62
13
F
63
14
F
64
15
F
65
Note5: The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
0
01
3
6-24
Not required
Adjustment remote commander
F
58, 5A to 65
40 to C0
03 to 70
90 to FD
Procedure
01
Set the data.
BD
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note5)
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Procedure
00
Set the data, and press PAUSE button.
00
Set the data.
Turn off the power and turn on
again